ATP Max XP

ATP Max XP
Main View 1 View 2 View 3
Warranty & Support
Financing Available
30-Day Guarantee
Need help choosing? Talk to a laser specialist — (800) 388-0850

Quick Specs

810nm
980nm
1064nm
915nm
650nm
Class
Class 4
Battery
No (AC-powered)
Weight
10lb
Best For
Human / Animal

The ATP Max XP is the flagship of the ATP Max line — a penta-wave Class 4 laser designed for advanced clinics and high-demand practices. Its five distinct wavelengths give the broadest spectrum of tissue interaction available in the ATP Max lineup, enabling deep tissue penetration, cellular activity enhancement, and versatile treatment options.

$19,950.00
In Stock Arrives in 2–3 Business Days
Warranty & Support
Financing Available
30-Day Guarantee

Key Features

Penta-wave platform: 810, 980, 1064, 915, and 650 nm for broad therapeutic coverage.
High-output performance: Up to 62 W for efficient, fast treatments.
Deep + superficial capabilities: Ideal for structural conditions and surface-level applications.
Touchscreen interface: Easy for any trained staff to operate reliably.
Efficient workflow: Short treatment times fit seamlessly into busy schedules.
Thermal safety controls: Intelligent cooling maintains comfort and protects tissue.
Portable clinical design: Easy to move between rooms and integrate into any practice.

About This Product

The ATP Max XP represents the flagship Penta-Wave Class 4 laser from ATP Max — built for advanced clinics, rehab centers, performance practices, and veterinary professionals who demand maximal therapeutic versatility, depth, and biological impact. Rather than being a one-dimensional “pain laser,” the XP is designed for comprehensive tissue healing, regeneration, and functional recovery — from deep structural work to superficial repair and long-term remodeling.

Wavelength & Power Configuration:

The XP combines five distinct wavelengths to target a full spectrum of tissue depths and cellular responses:

  • 810 nm @ 15 W — the gold-standard for photobiomodulation, highly absorbed by mitochondrial chromophores (e.g. cytochrome c oxidase), promoting ATP production, cellular respiration, and metabolic activation in deep tissues.
  • 980 nm @ 15 W — strong water absorption supports controlled thermal effects, vascular modulation, and enhanced circulation for deeper musculoskeletal structures or chronic tissue conditions.
  • 1064 nm @ 15 W — longest penetration depth of the set, delivering stable energy to dense, deep structures such as joints, tendons, ligaments, or deep muscle layers, facilitating structural remodeling and deep-tissue repair.
  • 915 nm @ 15 W — complements the infrared spectrum by broadening absorption peaks — particularly effective in hemoglobin and oxygen-rich tissues, supporting oxygen delivery, circulation, and deep tissue metabolism.
  • 650 nm (visible red) @ 2 W — targets superficial tissues, skin, fascia, scar tissue, or shallow neuromuscular interfaces for epithelial regeneration, dermal repair, wound support, and surface-level healing.

With a combined output of up to 62 W (continuous or pulsed), the XP delivers high photon density and energy throughput — enabling delivery of substantial joules in short sessions, while preserving flexibility to adjust depth, tissue type, and treatment goals.

Clinical Utility & Multi-Depth Strategy:

The penta-wavelength architecture of the XP allows a sophisticated, layered treatment strategy: from superficial dermatological and fascial applications (650 nm), to mitochondrial stimulation and cellular regeneration in mid-depth tissues (810 nm), to deep-structure remodeling for tendons, ligaments, joints or chronic musculoskeletal pathology (915, 980, 1064 nm). This makes the XP particularly suited for:

  • Chronic degenerative conditions — tendinopathies, ligament strain, joint wear, tendon remodeling.
  • Post-surgical rehabilitation — enhancing tissue recovery, reducing fibrosis risk, promoting vascularization and cellular regeneration.
  • Soft tissue injuries & overuse syndromes — muscle strains, tendon overload, fascia adhesions, chronic inflammation.
  • Veterinary and multi-species rehab — broad wavelength coverage adapts to varying tissue compositions.
  • Mixed-depth therapeutic protocols — surface healing + deep tissue regeneration in a single treatment session (or sequential protocol).

Operational Advantages:

The XP’s 10″ high-resolution touchscreen with advanced protocol navigation makes staff-friendly, repeatable treatments straightforward — ideal for busy clinics, multi-therapist practices, or mobile setups. The high-output configuration enables delivery of therapeutic-level joule doses in minimal time, supporting high patient throughput without sacrificing depth or efficacy. Integrated cooling and thermal safety control preserve tissue comfort even under high power, balancing safety with potency.

Philosophy: Regeneration over Quick Fixes

For providers who believe in treating root causes rather than masking symptoms, the XP is engineered as a tool for structural rehabilitation — not a quick analgesic. Its broad-spectrum wavelength coverage and powerful output enable a biologically coherent, depth-graded photobiomodulation approach. Rather than relying solely on thermal or nerve-modulation effects, the XP emphasizes mitochondrial activation, vascular support, tissue remodeling, and long-term healing. When used in a structured rehab program — be it post-op, chronic degeneration, or performance maintenance — the ATP Max XP becomes a high-output driver of regeneration, resilience, and functional restoration.

For clinics, physical therapy centers, sports-medicine practices, or veterinary rehab units that view laser therapy as a cornerstone of regenerative strategy — not just a quick pain-control addon — the ATP Max XP delivers unmatched wavelength diversity, power, and clinical flexibility in a single, portable platform.

What's Included

  • ATP Max XP Laser Console – penta-wave Class 4 platform with touchscreen control.
  • Protective Hard Case – foam-lined reinforced case for safe transport and storage.
  • Laser Safety Glasses (2 pairs) – eyewear for both operator and patient.
  • Handpiece / Emitter – primary treatment emitter included.
  • Power Supply & Cables – all components required for daily operation.
  • Training & Support – onboarding assistance, protocol guidance, and ongoing support.
Full Specifications
  • Laser Class: Class 4 therapeutic laser
  • Total Output: Up to 62 W
  • Wavelengths: 810 nm, 980 nm, 1064 nm, 915 nm, 650 nm
  • Operating Modes: Continuous wave (CW) and pulsed
  • Beam Type: High-intensity diode output
  • Control Interface: Full-color touchscreen with protocol navigation
  • Cooling: Integrated thermal management system
  • Power Input: 100–240V AC (international compatible)
  • Intended Use: Human and animal clinical environments
Shipping & Delivery

Orders typically ship within 1–2 business days from our U.S. warehouse.

Systems are shipped in a reinforced protective case and fully insured.

Signature required upon delivery for professional laser systems.

Warranty Information

5-Year Main Unit Warranty

Covers internal components and workmanship defects.

1-Year Emitter Warranty

Covers materials and workmanship for the emitter/handpiece.

Service and support are provided through the U.S.-based repair center.

Disclaimer

This device is intended for professional use by licensed clinicians or trained staff in accordance with applicable regulations.

Eye protection is mandatory for both operator and patient. Follow all Class 4 laser safety protocols.

The ATP Max XP is not a substitute for medical diagnosis or comprehensive medical care. Treatment outcomes vary based on condition and treatment plan.

Questions About ATP Max XP?

Our specialists are ready to help you find the right solution for your practice.

ATP Max XP
ATP Max XP $19,950.00

Frequently Asked Questions

Explore the most common questions about this system, compatibility, accessories, and treatment use cases.
01 What makes the ATPmax XP different from other Class 4 lasers?
The XP stands out by offering four separate infrared wavelengths (810, 980, 1064, and 915 nm) at 15W each, plus visible red light at 650 nm. Most lasers offer one or two active wavelengths—this system gives you full-spectrum depth control for treating everything from superficial injuries to deep musculoskeletal or neurological issues.
02 Does the XP support custom treatment settings?
Absolutely. While it includes a robust library of intelligent presets, you can also build and save your own custom protocols. This is ideal for practitioners who want to tailor sessions based on specific patient response or condition progression.
03 How does the 915 nm wavelength enhance treatment?
The 915 nm diode is a unique advantage in the XP lineup. It’s particularly effective at stimulating oxygen transport and hemoglobin activity, which helps support circulation and deeper tissue responses. When combined with the other three infrared wavelengths, it adds another dimension to the physiological impact of each session.
04 Is the ATPmax XP portable enough for mobile treatment?
Yes. Despite its power, the XP is compact and travel-friendly. The durable outer casing and internalized optics are designed for reliable use in clinics or on the road, and the device boots quickly for use in fast-paced or multi-location environments.
What Comes With It

Included with Your Purchase

Every order includes more than the device itself. From inventory and training to warranty help and ongoing support, this is built to make ownership straightforward.

Physical Inventory, Not Drop Shipped

Orders ship from Louisville, Colorado. We stock equipment ourselves, which means better control, better communication, and fewer surprises.

Straightforward Support

You get real help before and after the sale, including product guidance, setup support, training, and follow-up when questions come up.

Protocol Library Included

Each system includes access to a large protocol library with practical treatment guidance for common applications in both human and animal use.

Clear Pricing

If you are outside Colorado, the checkout total is the total. No extra sales tax is added afterward.

Warranty Coverage

Warranty length depends on the model, with coverage ranging from one to five years. If a problem comes up, support runs through us directly.

30-Day Trial Period

You have time to evaluate the system properly. Professional purchases are handled differently than home-use purchases, with home returns subject to a 15% restocking fee.

Marketing Materials for Professional Systems

Professional systems over $5,000 include ready-to-use marketing materials to help explain the technology and introduce it to patients.

A Better Ownership Experience

The goal is simple: make the process clear from day one, from shipping and setup to treatment use and long-term support.

Still have questions?

Talk with someone who knows the equipment and can help you sort through the details.